Product Information

SHM-25 + SHD2-08 Specifications

Rated thrust: 28N to 118N

[System Configuration]

No.NameDescription
Moving partConsists of a moving part (coil) and shaft (magnet).
DriverFor operating the moving part.
Power supply input terminalFor connecting the power cable. (Included in the driver)
Motor cableFor connecting the driver and the motor of the moving part. (Sold separately)
Encoder cableFor connecting the driver and the encoder of the moving part. (Sold separately)
Support softwareFor configuring and changing the settings of the driver on a PC. (Sold separately)
PC connection cableFor connecting to a PC. (Sold separately)
I/O connector setConnector for inputting/outputting command signals to the driver (Sold separately)

[Moving Part Specifications]

ModelSHM-252SHM-254SHM-256SHM-258
Number of coil sets2468
Rated thrust28 N59 N90 N118 N
Max. thrust126 N267 N403 N532 N
Max. speed4000 mm/s4000 mm/s3,500 mm/s2,600 mm/s
Rated current 1.2 A rms
Max. current 5.6 A rms
Time ratingContinuous
Ambient temperature 0 ~ 40 ℃
Ambient humidity 80% relative humidity or under (with no condensation)
Insulating resistance 500 VDC 10 M Ω or more
Dielectric strength voltage 1,500 VAC for 1 minute
Heat resistance class Class F (coil part)
Structure Fully-closed, self-cooling
Moving part mass0.70 kg1.10 kg1.60 kg2.00 kg

[Moving Part Dimensions]

Unit [mm]
ModelAPEffective stroke length
L = 472L=600L=728L=856L=984L=1112L=1240
SHM-25298602734015296577859131041
SHM-254150110221349477605733861989
SHM-256202162169297425553681809937
SHM-258254214117245373501629757885

[Driver Specifications]

ModelSHD2-08-252SHD2-08-254SHD2-08-256SHD2-08-258
Number of coil sets in moving part2468
Input voltage Main power supply: Three-phase 200 VAC, Control power supply: Single-phase 200 VAC
Input power supply range (common) 200 to 230 VAC +10 to -15% 50/60 Hz ± 5%
Rated continuous output current 1.22 A rms
Max. current (limit) 5.6 A rms
Max. instantaneous current (peak value) 8.0 A peak
Power supply equipment capacity0.9 kVA
Position command pulse inputSignal Line driver signal
Input method Select one from 2-pulse, 1-pulse, and 2-phase pulse
Max. frequency 4 M pulses/s
Input signal Total 20 dedicated inputs and general-purpose inputs
Output signal Total 20 dedicated outputs and general-purpose outputs
Limit function Speed limit, thrust limit, and movable range limit
Protection function Overload, overcurrent, overvoltage, sensor disconnection, memory error
Built-in positioning function Number of positioning points: 32, Number of speed settings: 32
Support software (SHD2-UTL) Parameter configuration, monitor display, program editing/configuration, saving data and transferring data to driver
Ambient temperature 0 ~ 40 ℃
Ambient humidity 80% relative humidity or under (with no condensation)
Mass 0.9 kg

[Driver Dimensions]