Options of PDC Models
Index Handle SD-Equipped
ハModels equipped with an index handle to allow easier reading of
handle turns. When the handle is rotated once, the little hand moves
one gradation. This makes it possible to minutely read handle turns.
Model |
Speed
changer
unit size |
Index handle model |
L1[mm] |
M1[mm] |
AK-90-MA-11-SD |
02 |
SD-53B-9L |
154.5 |
70 |
AK-124-MA-14N-SD |
04 |
SD-53B-90A-9L |
190 |
90 |
AK-140-MA-19N-SD |
07 |
SD-53B-90A-9L |
195 |
90 |
AK-155-MA-24N-SD |
15 |
SD-53B-90A-9L |
230 |
90 |
AK-185-MA-28N-SD |
22 |
SD-53B-90A-12L |
258 |
90 |
AK-216-MA-28N-SD |
37 |
SD-53B-90A-12L |
266 |
90 |
* For other dimensions, check the Specifications/Dimensions page for PDS.
Units with Remote Controllers
These are flexible-shaft remote controllers that can be used with belttype
stepless speed changer units to allow remote operation. They are
available as RFA type controllers, which have a flexible shaft in the
motor shaft axial direction, or as RFB type controllers, where the
flexible shaft is perpendicular to the motor shaft.
RFA-type
Speed changers
Unit size |
No. of
handle
turns |
Standard flexible
shaft length
[mm] | Model for motor-side
speed changer |
Remote
controller
RF model |
02(0.2kW) |
5 |
1000・1600・2500 |
AK-90-MA-11-RFA |
RFA-90-A |
04(0.4kW) |
5.5 |
1000・1600・2500 |
AK-124-MA-14N-RFA |
RFA-124-A |
07(0.75kW) |
7.5 |
1000・1600・2500 |
AK-140-MA-19N-RFA |
RFA-140-A |
15(1.5kW) |
8.5 |
1000・1600・2500 |
AK-155-MA-24N-RFA |
RFA-155-A |
22(2.2kW) |
10.5 |
1000・1600・2500 |
AK-185-MA-28N-RFA |
RFA-185-A |
37(3.7kW) |
8.5 |
1000・1600・2500 |
AK-216-MA-28N-RFA |
RFA-216-A |
RFB-type
Speed changers
Unit size |
No. of
handle
turns |
Standard flexible
shaft length
[mm] | Model for motor-side
speed changer |
Remote
controller
RF model |
02(0.2kW) |
10 |
1000・1600・2500 |
AK-90-MA-11-RFB |
|
RFB-90-A |
04(0.4kW) |
11 |
1000・1600・2500 |
AK-124-MA-14N-RFB |
|
RFB-124-A |
07(0.75kW) |
15 |
1000・1600・2500 |
AK-140-MA-19N-RFB |
|
RFB-140-A |
15(1.5kW) |
17 |
1000・1600・2500 |
AK-155-MA-24N-RFB |
|
RFB-155-A |
22(2.2kW) |
21 |
1000・1600・2500 |
AK-185-MA-28N-RFB |
|
RFB-185-A |
37(3.7kW) |
17 |
1000・1600・2500 |
AK-216-MA-28N-RFB |
|
RFB-216-A |
RFB-types allow you to choose the flexible shaft direction.
Items Checked for Design Purposes
Units with a remote controller have the following configuration with
regard to standard units.
- ・Motor-side speed changer for remote controller AK (RF)
- ・Remote Controllers RF
- ・Flexible shaft
- ・Index handle (Option)
Ensure that the curve of flexible shafts is within a radius of R300 mm.
If flexible shafts cannot be routed easily, place guides, etc. on the
flexible shafts.
Standard flexible shaft lengths are 1000, 1600, 2500 mm.
Consult Miki Pulley regarding lengths that are also available other than
standard length.
Motor Side Speed Changer AK (RF) for Remote Controller RF
These are dedicated motor side speed changers that allow the speed to be changed with an RF remote controller.
Model |
Speed changer
Unit size |
Common dimensions [mm] |
RFA dimensions[mm] |
RFB dimensions[mm] |
No. of handle turns |
A |
F |
K |
M |
N |
P |
Q |
B |
C |
D |
E |
G |
B |
C |
D |
E |
G |
H |
J |
L |
RFA |
RFB |
AK-90-MA-11-RF[ ] |
02 |
90 |
10 |
55 |
67 |
10 |
17 |
10 |
154 |
134 |
20 |
- |
6 |
171 |
149 |
22 |
78 |
4 |
20 |
62 |
70 |
5 |
10 |
AK-124-MA-14N-RF[ ] |
04 |
124 |
10 |
48 |
107 |
11 |
53 |
10 |
160 |
124 |
24 |
12 |
4 |
162 |
140 |
22 |
78 |
4 |
20 |
62 |
70 |
5.5 |
11 |
AK-140-MA-19N-RF[ ] |
07 |
140 |
10 |
48 |
112 |
15 |
53 |
10 |
169 |
133 |
24 |
12 |
4 |
171 |
149 |
22 |
78 |
4 |
20 |
62 |
70 |
7.5 |
15 |
AK-155-MA-24N-RF[ ] |
15 |
155 |
10 |
48 |
142 |
17 |
53 |
10 |
201 |
165 |
24 |
12 |
4 |
203 |
181 |
22 |
78 |
4 |
20 |
62 |
70 |
8.5 |
17 |
AK-185-MA-28N-RF[ ] |
22 |
185 |
10 |
53 |
165 |
21 |
62 |
10 |
228 |
192 |
24 |
12 |
4 |
230 |
208 |
22 |
78 |
4 |
20 |
62 |
70 |
10.5 |
21 |
AK-216-MA-28N-RF[ ] |
37 |
216 |
10 |
53 |
175 |
17.5 |
74 |
10 |
236 |
200 |
24 |
12 |
4 |
238 |
216 |
22 |
78 |
4 |
20 |
62 |
70 |
8.5 |
17 |
Remote Controller RF
Portion for flexible shaft-type remote controller.
Model |
Speed changer
Unit size |
Dimensions [mm] |
No. of handle turns |
A |
B |
B2 |
C |
D |
E |
F |
K |
L |
M |
N |
R |
R2 |
S |
T |
Z |
RFA |
RFB |
RFA-90-A / RFB-90-A |
02 |
100 |
75 |
81 |
25 |
10 |
82 |
20 |
38 |
70 |
10 |
14 |
70 |
70 |
25 |
11 |
7 |
5 |
10 |
RFA-124-A/RFB-124-A |
04 |
118 |
94 |
120 |
25 |
10 |
100 |
20 |
38 |
70 |
10 |
14 |
86 |
90 |
25 |
12 |
7 |
5.5 |
11 |
RFA-140-A/RFB-140-A |
07 |
118 |
94 |
120 |
25 |
10 |
100 |
20 |
38 |
70 |
10 |
14 |
86 |
90 |
25 |
12 |
7 |
7.5 |
15 |
RFA-155-A/RFB-155-A |
15 |
118 |
94 |
120 |
25 |
10 |
100 |
20 |
38 |
70 |
10 |
14 |
86 |
90 |
25 |
12 |
7 |
8.5 |
17 |
RFA-185-A/RFB-185-A |
22 |
118 |
104 |
131 |
25 |
10 |
100 |
20 |
38 |
70 |
13 |
18 |
86 |
90 |
25 |
12 |
7 |
10.5 |
21 |
RFA-216-A/RFB-216-A |
37 |
118 |
104 |
131 |
25 |
10 |
100 |
20 |
38 |
70 |
13 |
18 |
86 |
90 |
25 |
12 |
7 |
8.5 |
17 |
* Models listed in the “Model” column above are handle-only models (without a flexible shaft). To order models with an index handle, add “-A” to “-SD” to the end of the order.
Index Handle SD for Remote Operation Device RF
Model |
Applied index handle |
RFA |
RFB |
RFA-90-SD/RFB-90-SD |
SD-53B-9L |
SD-53B-12L |
RFA-124-SD/RFB-124-SD |
SD-53B-90A-9L |
SD-53B-90A-12L |
RFA-140-SD/RFB-140-SD |
SD-53B-90A-9L |
SD-53B-90A-16L |
RFA-155-SD/RFB-155-SD |
SD-53B-90A-9L |
SD-53B-90A-25L |
RFA-185-SD/RFB-185-SD |
SD-53B-90A-12L |
SD-53B-90A-25L |
RFA-216-SD/RFB-216-SD |
SD-53B-90A-12L |
SD-53B-90A-25L |
Handle Mounting Square Hole for Adjustment during Stop TH
Fine adjustments and positioning can be performed easily by using the handle inserted to this hole during machine stop.
Mount the adjustment handle for adjustment during stop TH to the square hole bushing of the PE model speed change pulley to perform fine adjustments and
positioning.
Please order an adjustment handle for adjustment during stop (TH-125- □ ) separately.
Dimensions When the Handle Is Attached to the PDG-BS Unit
Unit [mm]
Handle model |
Speed change pulley |
A |
B |
C |
D |
□F |
L |
X |
Z |
TH-125-12 |
PE-106 |
106 |
90 |
176 |
14 |
12 |
91 |
15 |
24 |
TH-125-12 |
PE-124 |
124 |
125 |
169 |
21 |
12 |
122 |
15 |
28 |
TH-125-15 |
PE-155 |
155 |
145 |
176 |
14 |
15 |
151 |
15 |
32 |
TH-125-15 |
PE-185 |
185 |
165 |
172 |
18 |
15 |
172 |
20 |
40 |
TH-125-15 |
PE-216 |
216 |
200 |
175 |
15 |
15 |
205 |
20 |
50 |
TH-125-15 |
PE-216 |
216 |
200 |
165 |
25 |
15 |
205 |
20 |
50 |