BEW Model, Terminal Block Type
This is the basic model of a power supply unit for controlling electromagnetic clutches and brakes with rated voltages of 45, 90, and 180 V DC. Whether connected to 100 V AC, 200 V AC, or 400 V AC,simply by connecting and inputting the power, you can obtain the DC voltage required to operate electromagnetic clutches and brakes. Options include half-wave rectification, full-wave rectification, and various other specifications.
[Specifications]
| Model | BEW-2G | BEW-4G | BEW-1R | BEW-2R | BEW-4R | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Input voltage | AC 100 V | ±10% 50/60 Hz |
● | ● | ● | ● | |||||||
| AC 200 V | ● | ● | ● | ● | |||||||||
| AC 400 V | ● | ● | ● | ||||||||||
| Input voltage range | Max. AC 280 V | Max. AC 480 V | AC 90–140 V | AC 180–280 V | 360–480 V AC | ||||||||
| Rectification method | Half-wave rectification | Half-wave | Full-wave | Semi-wave and full-wave rectification (shared) | |||||||||
| Half-wave | Full-wave | Half-wave | Full-wave | ||||||||||
| Output Voltage | DC 45 V | 90 V DC | DC 45 V | DC 90 V | DC 180 V | DC 45 V | DC 90 V | DC 90 V | DC 180 V | DC 180 V | DC 360 V | ||
| Output current | Ambient temperature: 20°C (values in parentheses are for 60°C) |
DC 1.0 A (DC 0.7 A) |
DC 1.0 A (DC 0.7 A) |
DC 2.0 A (DC 1.5 A) |
DC 1.0 A (DC 0.7 A) |
DC 0.7 A (DC 0.5 A) |
|||||||
| Output Capacity | At an ambient temperature of 20°C (values in parentheses are for 60°C) |
45W (25W) |
90W (50W) |
45W (25W) |
90W (50W) |
180W (100W) |
90W (50W) |
180W (100W) |
90W (50W) |
180W (100W) |
126W (90W) |
252W (180W) |
|
| Size Settings |
Voltage Specifications (Input voltage in parentheses) |
DC 45V (AC 100V) |
DC 90V (AC 200V) |
DC 45V (AC 100V) |
DC 90 V (AC 200 V) |
DC 180 V (AC 400 V) |
DC 45 V (AC 100 V) |
DC 90 V (AC 100 V) |
DC 90 V (AC 200 V) |
DC 180 V (AC 200 V) |
DC 180 V (AC 400 V) |
DC 360 V (AC 400 V) |
|
| ●: Applicable △: Applicable depending on clutch/brake model |
01 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||
| 02 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 03 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 04 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 05 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 06 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 08 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 10 | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | |||
| 12 | ● | ● | ● | ● | ● | ● | ● | ||||||
| 14 | ● | ● | ● | ● | ● | ● | ● | ||||||
| 16 | ● | ● | ● | ● | ● | ● | ● | ||||||
| 18 | △ | △ | ● | ● | △ | ● | ● | ||||||
| 20 | △ | △ | ● | ● | △ | ● | ● | ||||||
| 25 | △ | △ | ● | ● | △ | ● | ● | ||||||
| Applicable Clutches and Brakes |
Our electromagnetic clutches and brakes have rated voltages of 45/90/180 V DC |
Non-energized brakes | General | ||||||||||
| Insulation Resistance | Between terminals and main body | DC 500 V, 100 MΩ with megohmmeter | |||||||||||
| Dielectric Withstand Voltage | AC 1500 V, 50 Hz, 1 minute | AC 2000 V, 50 Hz, 1 minute | AC 1500 V, 50 Hz, 1 minute | AC 2000 V, 50 Hz, 1 minute | |||||||||
| Operating Environment | No condensation | -20 to +60°C | |||||||||||
| Weight | Per unit | 0.04 kg | |||||||||||
- 2. Unordered List (Asterisk) - 2
[Dimensions]
[Pins and Functions]
| Model | Terminal Symbol | Terminal Name | Function Description |
|---|---|---|---|
| BEW(G) | 1-2 | Power Input Terminal | Connect to commercial power supply |
| 2-3 | Control terminals | Controls the output by opening and closing the circuit between terminals using contacts such as relays | |
| 3-4 | Output terminals | Connect an electromagnetic clutch or brake. | |
| BEW(R) | 1-2 | Power input terminals | Connect to commercial power supply |
| 2-4 | Output Terminal (Half-Wave) | Connect the electromagnetic clutch/brake (for half-wave rectification) | |
| 3-4 | Output terminal (full-wave) | Connect the electromagnetic clutch/brake (for full-wave rectification) |
- 5. Unordered List (Asterisk) - 2