Product Information

126 Models Clutch/Brake Units - Motor-coupled Type

ダウンロード

126 Models Clutch/Brake Units - Motor-coupled Type Specifications

126-□-4B Types

[Specifications]

ModelSizeMotor output[kW]
4P
Dynamic friction torque Td
[N・m]
Static friction torque Ts
[N・m]
Coil(at20℃)Heat resistance classRotating part moment of inertia
[kg・m2]
Total work performed until readjustment of the air gap ET
[J]
Armature pull-in time
ta[s]
Torque build-up time
tp[s]
Torque decaying time
td[s]
Mass
[kg]
Voltage
[V]
Wattage
[W]
Current
[A]
Resistance
[Ω]
126-06-4B-0.2kW060.255.5DC24110.4652B1.28×10-436×106C:0.020
B:0.015
C:0.041
B:0.033
C:0.020
B:0.015
8.9
126-08-4B-0.4kW080.41011DC24150.6338B3.70×10-460×106C:0.023
B:0.016
C:0.051
B:0.042
C:0.030
B:0.025
13
126-10-4B-0.75kW-IE3100.752022DC24200.8329B1.40×10-3130×106C:0.025
B:0.018
C:0.063
B:0.056
C:0.050
B:0.030
20
126-12-4B-1.5kW-IE3121.54045DC24251.0423B3.85×10-3250×106C:0.040
B:0.027
C:0.115
B:0.090
C:0.065
B:0.050
41
126-16-4B-2.2kW-IE3162.28090DC24351.4616B1.35×10-2470×106C:0.050
B:0.035
C:0.160
B:0.127
C:0.085
B:0.055
54
126-16-4B-3.7kW-IE3163.78090DC24351.4616B1.35×10-2470×106C:0.050
B:0.035
C:0.160
B:0.127
C:0.085
B:0.055
69

*The induction motors are fully sealed external fan motors that conform to the JIS C4210 standard (for 0.2 kW and 0.4 kW models) or the JIS C 4213 standard (for 0.75 kW models or higher).

*The power supplies for the motors are 3-phase, 200 V AC at 50 Hz, or 200/220 V AC at 60 Hz.

*If you desire a special voltage (5 Power Supply Specifications), different number of poles, or the like for the induction motor, contact Miki Pulley.

*The dynamic friction torque, Td, is measured at a relative speed of 100 min-1. Depending on the initial torque characteristics, break-in to condition the engaging surfaces may also be required.

[Dimensions]

Unit [mm]
ModelDimensions of partDimensions of shaft
A1A2B1B2CD1D2EF1F2GJKLHTYZ1Z2QSUVW
126-06-4B-0.2kW6590901056510013027.5612.648.5102335313.56.5251112.5M4×0.7length84
126-08-4B-0.4kW801101101308012514532.572126.53.263127.5389167.52.515.59301416M4×0.7length85
126-10-4B-0.75kW-IE31051351401609015016335811363.28015446218432011.5401921M6×1length115
126-12-4B-1.5kW-IE3135160175185112190182/17642.597148.515108194550.5244.5324.511.5502427M6×1length117
126-16-4B-2.2kW-IE3155200200230132230198/19545109155.518135256649.528642814502427M6×1length117
126-16-4B-3.7kW-IE3155200200230132230225/21545109168.51814525668129542814602831M6×1length117

*The output shaft keyways are old JIS standard class 2 while the key is old JIS standard class 1.

*When inserting pulleys or the like onto output shafts, use the supplied insertion set.

*These models are cast basded on a motor output of 1.5 kW or greater.

126-□-4F-N Types

[Specifications]

ModelSizeMotor output
[kW]
4P
Dynamic friction torque Td
[N・m]
Static friction torque Ts
[N・m]
Coil(at20℃)Heat resistance classRotating part moment of inertia
[kg・m2]
Total work performed until readjustment of the air gap ET
[J]
Armature pull-in time ta[s]Torque build-up time
tp[s]
Torque decaying time
td[s]
Mass
[kg]
Voltage
[V]
Wattage
[W]
Current
[A]
Resistance
[Ω]
126-06-4F-N-0.2kW060.255.5DC24110.4652B1.28×10-436×106C:0.020
B:0.015
C:0.041
B:0.033
C:0.020
B:0.015
8.9
126-08-4F-N-0.4kW080.41011DC24150.6338B3.70×10-460×106C:0.023
B:0.016
C:0.051
B:0.042
C:0.030
B:0.025
13
126-10-4F-N-0.75kW-IE3100.752022DC24200.8329B1.40×10-3130×106C:0.025
B:0.018
C:0.063
B:0.056
C:0.050
B:0.030
20
126-12-4F-N-1.5kW-IE3121.54045DC24251.0423B3.85×10-3250×106C:0.040
B:0.027
C:0.115
B:0.090
C:0.065
B:0.050
41
126-16-4F-N-2.2kW-IE3162.28090DC24351.4616B1.35×10-2470×106C:0.050
B:0.035
C:0.160
B:0.127
C:0.085
B:0.055
54
126-16-4F-N-3.7kW-IE3163.78090DC24351.4616B1.35×10-2470×106C:0.050
B:0.035
C:0.160
B:0.127
C:0.085
B:0.055
69

*The induction motors are fully sealed external fan motors that conform to the JIS C4210 standard (for 0.2 kW and 0.4 kW models) or the JIS C 4213 standard (for 0.75 kW models or higher).

*The power supplies for the motors are 3-phase, 200 V AC at 50 Hz, or 200/220 V AC at 60 Hz.

*If you desire a special voltage (5 Power Supply Specifications), different number of poles, or the like for the induction motor, contact Miki Pulley.

*The dynamic friction torque, Td, is measured at a relative speed of 100 min-1. Depending on the initial torque characteristics, break-in to condition the engaging surfaces may also be required.

[Dimensions]

Unit [mm]
ModelDimensions of partDimensions of shaft
A1A2D1D2D3D4FGKLTYZQ1Q2SUVW
126-06-4F-N-0.2kW90°45°16013011013081073353.51023251112.5M4×0.7length84
126-08-4F-N-0.4kW90°45°16014511013012410130.53893.51030301416M4×0.7length85
126-10-4F-N-0.75kW-IE390°45°20016313016513112157.54633.51240401921.5M6×1length116
126-12-4F-N-1.5kW-IE390°45°200182/176130165148.512197.55511333.51250502427M6×1length118
126-16-4F-N-2.2kW-IE390°45°250198/195180215155.516260.566015441560602831M6×1length118
126-16-4F-N-3.7kW-IE390°45°250225/215180215168.516260.5681.516341560602831M6×1length118

※Flange and output shaft dimensions are in conformance with IEC、JEM standard flange motors. (Size 06 has keys and keyways)

※When inserting a pulley into the output shaft, please use the attached insertion set.

Related Product